Product
Steam Coil Air Preheater (SCAPH)
Finned steam coils that preheat combustion air — recovering boiler steam energy and protecting downstream air heaters in fouling-prone flue gas.
What is a steam coil air preheater?
A steam coil air preheater (SCAPH) is a finned-tube, steam-to-air heat exchanger. Saturated (or suitable process) steam flows inside the tubes; combustion air crosses the external fins and picks up heat. Units are typically installed in the FD-fan duct, ahead of the main tubular or regenerative air preheater.
Grandeh fabricates next-generation G-type finned tube SCAPH coils for industrial steam service — with attention to thermal duty, drainability and IBR-aligned pressure-part practice at Aurangabad works.
Why plants specify SCAPH
- Raise combustion-air temperature during start-up and low-load when flue gas alone is not enough
- Help keep main-APH cold-end surfaces warmer — reducing acid dew-point corrosion risk
- Protect tubular / regenerative APHs when flue gas is sticky, acidic or ash-laden (spent-wash, biomass)
- Stabilise air temperature for combustion and burner performance where plant procedures allow
How SCAPH works
- Steam side — steam enters the inlet header, distributes through the tube bundle and condenses as it releases latent heat
- Air side — the FD fan drives ambient or process air across the fins; warmed air continues to the main APH or furnace
- Condensate — drains through the return header, traps and vents so coils stay free of water hammer and air locking
Main components
A complete SCAPH package combines heat-transfer hardware with drainage, control and duct interfaces. Grandeh fabricates the coil, headers and casing; valves, instruments and actuators are integrated to project preference.
| Component | Role |
|---|---|
| Finned tube bundle | Primary steam-to-air heat transfer (G-type / spiral fins) |
| Steam inlet header | Even steam distribution into the coil tubes |
| Return header | Collects condensate from the tube rows |
| Condensate drains & vents | Removes condensate and non-condensables; limits water hammer |
| Casing / duct housing | Supports the coil and guides airflow with low leakage |
| Steam control valve | Modulates heating capacity to air-outlet temperature |
| Temperature / pressure instruments | Air and steam monitoring for control and diagnostics |
| Air bypass damper | Bypasses the coil when preheating is not required — see also Grandeh dampers |
| Supports & expansion joints | Carry mechanical loads and thermal movement |
What information is required to size SCAPH?
Accurate selection needs verified air-side, steam-side and site data — for design, start-up and low-load cases where relevant.
Air-side design data
- Air mass or volumetric flow (kg/s, Nm³/h or m³/h)
- Inlet-air temperature (°C) — including minimum ambient / design case
- Required outlet-air temperature or temperature lift (°C)
- Maximum allowable air-side pressure drop (Pa or mmWC)
- Dust, moisture or contaminants in the air stream
- Duct width, height, orientation and available length
Steam and condensate data
- Available steam pressure (bar) and temperature (°C)
- Saturated or superheated condition; available steam flow limits
- Required heat duty (kW) if already calculated
- Condensate return pressure and preferred trap / drain routing
Mechanical and site data
- Preferred tube, fin, header and casing materials
- Horizontal or vertical coil orientation; maintenance / pull-out clearance
- Flange standards, connection sizes and support arrangement
- IBR / TPI / documentation scope for the purchase order
Share process data and duct sketches with your enquiry — we will propose coil rows, face velocity and materials that fit fan and steam limits.
Technical focus
| Parameter | Grandeh SCAPH practice |
|---|---|
| Equipment type | Steam-to-air finned-tube heat exchanger |
| Coil type | G-type / spiral finned tubes |
| Heating medium | Saturated or suitable process steam |
| Heated medium | Combustion / ambient / process air |
| Typical service | Spent-wash / slop, biomass, cold start-up, low load |
| Design care | Drainable circuits, header sizing, air-side ΔP within fan limits |
| Compliance | IBR-aligned pressure-part practice |
| Works | Shendra MIDC, Aurangabad — ISO 9001 fabrication |
Available materials
Material selection follows steam pressure/temperature, condensate corrosivity and plant preference. Typical options include:
- Tubes: Carbon steel (e.g. SA-210) for standard steam service; stainless SS304 / SS316 / SS316L where condensate or process atmosphere demands higher corrosion resistance; copper or cupro-nickel for selected low-temperature or specialty duties.
- Fins: Aluminium for high conductivity and weight economy; copper for demanding heat transfer; stainless fins where mechanical or corrosion duty requires it.
- Headers & connections: SA-106 Grade B or equivalent carbon steel as default; stainless headers on request for corrosive condensate return paths.
- Casings / frames: Carbon steel with protective coating, or stainless where specified for outdoor or aggressive plant atmospheres.
Final metallurgy is confirmed against your P&ID, steam quality and inspection agency requirements.
Testing and documentation
Grandeh supports project QA with fabrication and inspection documentation aligned to industrial EPC practice:
- Dimensional inspection and coil hydrostatic / pneumatic testing as specified
- Material test certificates (MTC) for pressure parts
- Welding procedure / welder qualification records where applicable
- GA drawings, coil data sheets and as-built documents for site erection
- Third-party inspection (TPI) coordination — e.g. Bureau Veritas, TÜV, LRQA — when called in the purchase order
- Quality documents available to project partners via Grandeh project portal
Typical applications
- Spent-wash / slop-fired boiler combustion-air heating
- Biomass and high-moisture fuel boilers
- Cold-climate and start-up air heating for package and field-erected boilers
- Corrosion protection of downstream tubular / regenerative APHs
Industries we serve with SCAPH
- Distillery — spent-wash / slop-fired boiler air heating
- Sugar and process cogeneration boilers
- Power and captive power cold-start air heating
- Boiler OEMs — package and field-erected supply
See a recent dispatch: SCAPH coils for distillery / process duty.
FAQ
When should a plant use SCAPH instead of only a tubular APH?
When flue gas is sticky, acidic or ash-laden — common in spent-wash and some biomass boilers — or when start-up / low-load air heating is needed before the main APH is effective.
What data is required to size a SCAPH?
Air flow and temperatures, allowable air-side pressure drop, steam pressure and quality, condensate return conditions, duct size / layout, and material or inspection preferences.
How does SCAPH help with cold-end corrosion?
By lifting combustion-air temperature before the main air preheater, SCAPH helps keep cold-end metal surfaces warmer and reduces acid condensation risk on tubular or regenerative APH surfaces.
What materials does Grandeh use for SCAPH?
Carbon-steel or stainless tubes, aluminium / copper / stainless fins, and SA-106 (or stainless) headers are typical. We confirm the bill of materials against your steam and site conditions.
Can SCAPH be supplied with a new boiler or as a retrofit?
Both. Share steam pressure, air flow, required temperature lift and duct layout for sizing.
Do you support TPI and IBR documentation?
Yes. Pressure-part practice is IBR-aligned at our Aurangabad works, and we coordinate hold points with client or third-party inspectors as specified.